Profile Selection Guide

Profile Selection Guide

The Way Forward

Contact Fielders® design team through your local Commercial Roofing Representative in each state to discuss the wide range of opportunities open to you. The backing of a team of experienced quality engineers ensures that the solutions offered can be fully tested to the relevant Australian standards and meet the design criteria of your specific project needs.

Your problem – our solution. Finish on top with Fielders®.

Windload by Region

To determine a profile's windloads and spans for your region please refer to the relevant tables containing profile-specific data in the manual. For assistance in determining the best solution please contact your local Fielders® representative.

Finesse Roofing and Walling Profile Selection Guide

ProfileBMT
(mm)
Cover width Depth of
Rib (mm)
Minimum
Recommended
Roof Pitch (mm)
Max. Recommended
Spacing of Supports for Roof Spans for Normal Conditions (mm)
Max. Recommended
Spacing of Supports for Wall Spans for Normal Conditions (mm)
Watertight Guarantee Period (years) Availability
SingleEndInternalSingleEndInternal
SHADOWLINE™ 305 NON-CYCLONIC Profile
Shadowline™ 305
0.703054818002000250025002700270020 yrsNationally (except WA)
SHADOWLINE™ WA NON-CYCLONIC Profile
Shadowline™ WA
0.703054818002000250025002700270020 yrsWA
NEO ROMAN™ NON-CYCLONIC Profile
Neo Roman™
0.55 27525Must be fixed to Structural Ply at max 600mm c/c only for wind region A and terrain category 3 for higher wind regions, check with your Fielders representative.N/ANationally
475
PROMINENCE™ NON-CYCLONIC Profile
Prominence™
0.55 up to 265386006006009009001200N/ANationally
0.75700700700100010001300Nationally (MOQ may apply)
0.55 46538Fixed to Ply at 450mm c/c 450450450Nationally
0.75550550550Nationally (MOQ may apply)
CADENCE™ NON-CYCLONIC Profile
CADENCE®
TBA
BOULEVARD™ NON-CYCLONIC Profile
Boulevard™
0.55 up to 28525N/A Walls only 120012001500N/ANationally
0.75130012001500Nationally (MOQ may apply)
0.55 485259009001200Nationally
0.75100010001300Nationally (MOQ may apply)
GRANDEUR™ NON-CYCLONIC Profile
Grandeur®
0.55 325271° (3° degrees for end lapped roofs )For all span type:
Fixed clip at 350 at roof edge.
Sliding clip at 700 at general area.
For all span type:
Fixed clip at 350 at roof edge.
Sliding clip at 700 at general area.
N/ANationally
0.75For all span type:
Fixed clip at 450 at roof edge.
Sliding clip at 800 at general area.
For all span type:
Fixed clip at 450 at roof edge.
Sliding clip at 800 at general area.
Nationally (MOQ may apply)
0.55 52527Not Suitable for roofing applications For all span type:
Fixed clip at 350 at roof edge.
Sliding clip at 700 at general area.
Nationally
0.75For all span type:
Fixed clip at 450 at roof edge.
Sliding clip at 800 at general area.
Nationally (MOQ may apply)
Notes:
  1. The above span information is to be used as a guide only. Spans have been based on a Region A location with a Terrain Category of 3 as per AS1170.2. All capacities shall be confirmed for each project by referring to Specifying Fielders® – Finesse manual or your local Fielders® representative.